Назад
Загрузка

Цена

от
до
Сбросить фильтр Применить

Текстовый блок

Это текстовый блок. Меняется в меню Веб-сайт → Текстовые блоки. 

HI96721С колориметр на железо, 0.00-5.00 мг/л (набор)

Артикул HI96721С колориметр на железо, 0.00-5.00 мг/л (набор)
   
50 383 p
В наличии: 0 шт.
Купить в 1 клик
Мы принимаем к оплате:
Задать вопрос по продукту

Описание товара

Краткое описание:

The HI96721 Iron High Range Photometer combines accuracy and ease of use in an ergonomic, portable design. Using the HI93721-01 ready made reagents the user can accurately determine the concentration of iron in freshwater samples within a 0.00 to 5.00 mg/L (ppm) range. The HI96721 offers many advanced features including the exclusive CAL Check function used for performance verification and calibration of the meter.

CAL Check Validation and Calibration

Built-in Timer

Automatic shut off


Range: 0.00 to 5.00 mg/L (ppm)
Resolution: 0.01 mg/L
Accuracy @ 25 C (77 F): ±0.04 mg/L ±2% of reading
Light Source: light emitting diode
Light Detector: silicon photocell with narrow band interference filter @ 525 nm
Method: adaptation of the USEPA method 315B (phenanthroline) and Standard Method 3500-Fe B
Auto-off: after ten minutes of non-use in measurement mode after one hour of non-use in calibration mode with last reading reminder
Environment: 0 to 50 C (32 to 122 F) RH max 95% non-condensing
Battery Type: 9V battery
Dimensions: 193 x 104 x 69 mm (7.6 x 4.1 x 2.7)
Weight: 360g (12.7oz.)
Ordering Information: HI96721 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.

The HI96721 portable photometer is for the measurement of iron in freshwater samples. Hanna's portable photometers feature an advanced optical system the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is ins erted into the measurement cell in the same position every time to maintain a consistent path length.

Features at-a-glance

CAL Check - Allows for performance verification and calibration of the meter using NIST traceable standards.

GLP - Review of the last calibration date

Auto-shut off - Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.

Battery status indicator - Indicates the amount of battery life left.

Built in timer - Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed.

Error messages - Messages on display alerting to problems including no cap, high zero, and standard to low.

Cooling lamp indicator - To maintain the desirable wavelength to be used for absorbance it is necessary to ensure component are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken.

Units of measure - Appropriate unit of measure is displayed along with reading.

Iron is naturally present in water in low concentrations, but it reaches high concentrations in wastewater e±uents. The iron concentration in water needs to be monitored because it becomes harmful above certain levels. In domestic water, for instance, iron can unpleasantly alter the taste, stain laundry, damage kitchenware and favor the growth of certain bacteria. Iron is also an indicator of ongoing corrosion in water cooling and heating systems. Moreover, iron is normally monitored in mining wastewater to avoid contamination

The HI96721 uses an adaptation of USEPA Method 315B (phenanthroline) for natural and treated waters, and Standard Method 3500-Fe B for water and wastewater to measure iron concentrations in the 0.00 to 5.00 mg/L (ppm) range. These methods require a reagent that contains both a reducing and a complexing agent. The reagent converts all but very most resistant forms of iron present in the sample to the ferrous (Fe2?) or soluble state. The reagent when added to a sample containing iron will turn the sample an orange hue the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For iron, a narrow band interference filter at 525 nm (green) allows only green light to be detected by the silicon photodetector. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

The HI96721 is available as a kit which includes:

  • Portable Photometer
  • Sample cuvettes (2)
  • Caps (2)
  • CAL Check standards with certificate
  • Cuvette cleaning cloth
  • Rugged carrying case
  • Thermoformed insert for meter and accessories
*Reagents ordered separately

CAL Check standards with certificate

The HI96721-11 CAL Checkstandards are used for calibration and performance verification of photometers with the CAL Check function.

Supplied with Certificate of Analysis
  • Lot number
  • Expiration date
  • Standard val ue @ 25 C
  • Reference meter NIST traceable
Provided storage containers
  • Light tight
  • Protects from accidental breakage
 
"
Характеристики